New diagnostic test can detect chlamydia trachomatis in less than 20 minutes

Researchers have developed a new assay for rapid and sensitive detection of Chlamydia trachomatis, the most common sexually transmitted infection (STI) in humans. This procedure takes less than 20 minutes and can be easily performed at the point of care…

Researchers have developed a new assay for rapid and sensitive detection of Chlamydia trachomatis, the most common sexually transmitted infection (STI) in humans. This procedure takes less than 20 minutes and can be easily performed at the point of care (POC) during the patient’s visit, reports The Journal of Molecular Diagnostics.

C. trachomatis affects 5% to 10% of the population and is particularly common in young adults under 25 years. It is a major public health concern due to its prevalence and potential severe long-term consequences. One of the main reasons it is so prevalent is that in the majority of cases (75% of women and 50% of men) there are minimal to no symptoms, and it therefore often goes undiagnosed. Infection is associated with non-gonococcal urethritis in men and several inflammatory reproductive tract syndromes in women such as inflammation of the uterine cervix and pelvic inflammatory disease. Untreated, the infection increases the risk of ectopic pregnancy and is one of the leading causes of female infertility worldwide.

The assay uses recombinase polymerase amplification (RPA), a nucleic acid amplification technique (NAAT), to detect C. trachomatis directly from urine samples. Because the assay’s novel approach does not require the purification of total DNA from the urine sample, the need for specialized equipment is eliminated. The procedure is significantly less laborious, less time-consuming, and consequently less expensive. It is relatively simple to perform and could therefore be applied in numerous POC settings.

“The assay enables highly specific C. trachomatis detection with sensitivity levels significantly improved compared to currently available C. trachomatis POC assays,” says Ülo Langel, PhD, Professor of Molecular Biotechnology, University of Tartu, Estonia, and Professor of Neurochemistry, Stockholm University, Sweden.

Existing polymerase chain reaction (PCR)-based techniques for testing C. trachomatis are widely applied but are only suitable for use in hospitals with trained staff and expensive machinery. Studies have shown that up to 50% of patients never return to get the diagnostic result or required treatment.

Although several rapid-diagnosis POC tests have already been developed, none offer a comparable sensitivity to hospital-based techniques. Recent independent studies have shown that currently available POC tests have a sensitivity of just 10% to 40%. Initial analysis of the new assay’s performance indicated a specificity of 100% and a sensitivity of 83%, evidence of its potential reliability.

“The alarmingly poor performance of the available POC tests for C. trachomatis has limited their wider use, and there is a clear requirement for more sensitive and cost-effective diagnostic platforms. Hence, the need for an applicable on-site test that offers reasonably sensitive detection,” concludes Prof. Langel.

TECHNICAL DETAILS OF THE STUDY

Recombinase polymerase amplification (RPA) is a nucleic acid amplification technique (NAAT) – a laboratory technique that involves the in vitro synthesis of many copies of DNA or RNA from one original template. These techniques have revolutionized diagnostic technology. Current technologies that allow the detection of amplification in real time are fast becoming diagnostic industry standards.

C. trachomatis cells contain plasmids (small DNA molecules that are separate from chromosomal DNA) that have a number of coding sequences. For identification and amplification by RPA, researchers selected a gene fragment within a gene (CDS2) that was conserved across sexually transmitted C. trachomatis strains. The assay does not require the purification of total DNA from the urine sample. Heating the sample for five minutes at 90°C is enough to release a sufficient amount of the amplification target to determine whether the pathogen is present. Urine contains polymerase chain reaction (PCR) inhibitors, but up to 5 μl of urine can be added without affecting sensitivity of the RPA, whereas the addition of 10 μl affects amplification efficiency significantly.

The C. trachomatis assay developed here was able to detect at least 50 copies of the CDS2 target. C. trachomatis harbors, on average, between four and ten copies of the plasmid per elementary body depending on the strain and development stage. The lowest detectable amount of the C. trachomatis RPA assay can therefore be translated to 5 to 12 pathogens per reaction and is in the same range as other nucleic acid amplification-based techniques.

The assay was tested on urine samples from 70 patients (51 females and 19 males) attending a sexual health clinic in Estonia. The samples were tested in parallel using RPA and Roche Cobas Amplicor C. trachomatis assays.

Fifty-eight samples tested negative in both assays. As no false negatives were detected, the clinical specificity of the C. trachomatis RPA assay can be estimated at 100%.

Twelve of the samples tested as positive using the Roche assay. Of these, 10 tested positive and two tested negative in the RPA reaction. Based on these results, the clinical sensitivity of the RPA assay can be estimated at 83%.

Of the 12 patients who tested positive, three complained of symptoms. The other nine patients were asymptomatic. Of the 58 C. trachomatis-negative patients, 15 (26%) complained of symptoms that could be associated with C. trachomatis infection. One of these tested positive for N. gonorrhoeae and M. genitalium. Others were diagnosed with bladder inflammation (two patients), bacterial vaginosis (five patients), yeast infection (four patients), or abdominal pain of non-gynecological origins (three patients).

Elsevier Health Sciences
Article adapted by Medical News Today from original press release. Click ‘references’ tab above for source.
Visit our
Medical Devices / Diagnostics category page for the latest news on this subject.Please use one of the following formats to cite this article in your essay, paper or report:
MLASciences, Elsevier Health. “New diagnostic test can detect chlamydia trachomatis in less than 20 minutes.” Medical News Today. MediLexicon, Intl., 17 Dec. 2013. Web.17 Dec. 2013. <http://www.medicalnewstoday.com/releases/270170>
APASciences, E. (2013, December 17). “New diagnostic test can detect chlamydia trachomatis in less than 20 minutes.” Medical News Today. Retrieved fromhttp://www.medicalnewstoday.com/releases/270170.Please note: If no author information is provided, the source is cited instead.

Rate this article (click to rate)
New diagnostic test can detect chlamydia trachomatis in less than 20 minutes

Health Professionals:

 
(0 votes)

Public / Patient:

 
(0 votes)

Add Your Opinion On This ArticleJoin the discussuon
Please note that we publish the name you give us, but we do not publish your email address. We will email you to let you know when your comment has been published but will not use it for any other purpose. Please see our privacy policy for more information.
If you write about specific medications, operations, or procedures please do not name healthcare professionals by name.

Contact our news editors
For any corrections of factual information, or to contact the our editorial team, please use our feedback form. Please send any medical news or health news press releases to:

Note: Any medical information published on this website is not intended as a substitute for informed medical advice and you should not take any action before consulting with a health care professional. For more information, please read our terms and conditions.

Scroll to top

This page was printed from: http://www.medicalnewstoday.com/releases/270170.php

Visit www.medicalnewstoday.com for medical news and health news headlines posted throughout the day, every day.
© 2004-2013 All rights reserved. MNT (logo) is the registered trade mark of MediLexicon International Limited.